Network OS Documentation Update 27
53-1002606-06
Modified messages
3
Probable Cause Indicates that the vCenter discovery timeout duration has been changed.
Recommended
Action
No action is required.
Severity INFO
Modified messages
Replace the following message in the chapter FCOE System Messages on page 60.
FCOE-1034
Message <timestamp>, [FCOE-1034], <sequence-number>,, WARNING, <switch-name>, FIP/FCoE
frame on priority <pkt_ctrlp->pri_in> for <Name of the following string> <MAC
address or WWN of the source device> on interface <Rbridge-id>/<Slot>/<Port>
discarded because PFC/FCoE not enabled on this priority.
Probable Cause Indicates that the priority is not PFC or FCoE enabled.
Recommended
Action
Configure as required.
Severity WARNING
Vue de la page 36