302 Brocade MLX Series and NetIron XMR Hardware Installation Guide
53-1002373-02
Verifying proper operation
4
The Status column shows the module status. The management module status can be one of the
following:
ACTIVE – The module is currently the active management module.
STANDBY – The module is currently the standby management module.
COMING UP – The module is coming up as the standby module. This status occurs if the
standby management module becomes the active module during a switchover.
The switch fabric module status can be one of the following:
ACTIVE – The module is up and running.
BAD – The management module cannot initialize the switch fabric module.
An interface module status can be one of the following:
CARD_STATE_INIT – The system detects the module but the module is not up and running yet.
CARD_STATE_BOOT – The module is booting.
CARD_STATE_INTERACTIVE – The module is booting from interactive mode.
CARD_STATE_LP_SYNC – The software images are synchronized between the management
module and interface module.
CARD_STATE_SYNC – The system is currently synchronizing the software image between the
management module and interface module.
CARD_STATE_SOFTWARE_LOADED – The module has loaded the software image.
CARD_STATE_POWER_OFF – The module does not have power.
CARD_STATE_UP – The module is operating normally.
CARD_STATE_FAILED – The management module was unable to bring up an interface module.
If you see this status, make certain that the interface module is installed properly. For more
information, refer to “Installing Brocade NetIron XMR 4000 modules” on page 245, “Installing
Brocade NetIron XMR 8000 modules” on page 255, “Installing Brocade NetIron XMR 16000
modules” on page 265, or “Installing Brocade NetIron XMR 32000 modules” on page 277.
CARD_DOWN_REASON_<explanation> – The module is in a nonfunctional state. This status
appears with an explanation for why the module is down. For example,
“CARD_DOWN_REASON_BOOT_FAILED.” If the explanation does not help you resolve the
problem, contact technical support and provide the explanation included with this status.