84 Fabric Watch Administrator’s Guide
53-1002153-01
Switch monitoring
8
Switch status policy planning
Fabric Watch monitors the health of the switch under various classes. Table 28 lists the current
overall switch status policy parameters in a switch and identifies the factors that affect their health.
Note that not all switches use the listed monitors.
The default setting for a MARGINAL state is 0, which prevents Fabric Watch from generating
notifications due to missing power supplies. For configurations with a 2+2 power suppy
combination, we recommend you change the default Fabric Watch default setting of 0 to 2 power
supplies (PS), which forces the overall switch status to a MARGINAL state.
Use the switchstatusPolicySet command to manually change the policy setting. Refer to the FOS
Command Reference Manual for more information.
Implementing your switch status policy
After you plan and define your switch status policy, implement it using the following procedure.
1. Enter the switchStatusPolicySet command to configure each policy.
Each policy has two parameters that can be configured: Marginal and Down.
2. Set the number of units Marginal or Down based on your system requirements for each policy
or parameter.
TABLE 28 Switch status policy factors
Monitor Health factors
Power Supplies Power supply thresholds detect absent or failed power supplies, and power supplies that are
not in the correct slot for redundancy.
The presence of four or more FS8-18 encryption blades in the DCX Data Center Backbone
causes the Fabric Watch switch status policy for power supplies to assume a policy setting
of 2,1, as with the blades listed above. Use the switchStatusPolicySet command if you need
to manually change the policy setting.
Temperatures Temperature thresholds, faulty temperature sensors.
Fans Fan thresholds, faulty fans.
WWN Faulty WWN card (applies to modular switches).
CP Switch does not have a redundant CP (applies to modular switches).
Blades Faulty blades (applies to modular switches).
Core Blade Faulty core blades.
Flash Flash thresholds.
Marginal Ports
1
Port, E_Port, FOP_port (optical), and FCU_Port (copper) port thresholds. Whenever these
thresholds are persistently high, the port is Marginal.
Faulty Ports
1
Hardware-related port faults.
Missing SFPs
1
Ports that are missing SFP media.
Error Ports1 Ports with errors.
1
Marginal ports, faulty ports, error ports, and missing SFPs are calculated as a percentage of the physical ports
(excluding FCoE and VE_Ports).