Brocade Communications Systems 8/80 Manuel de service Page 128

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 133
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 127
104 Fabric Watch Administrator’s Guide
53-1002153-01
Port Detail report
10
219 VE HEALTHY 003:37 - - - - - - - - - - - - -
220 VE HEALTHY 002:48 - - - - - - - - - - - - -
221 VE HEALTHY 061:19 - - - - - - - - - - - - -
222 VE HEALTHY 061:19 - - - - - - - - - - - - -
223 VE HEALTHY 061:19 - - - - - - - - - - - - -
Output of the Port Detail report depends on the ports that belong to the current Admin Domain
context. If a port does not belong to the current Admin Domain, nothing other than the port number
is displayed for that port.
Example:
“000 ----------------Not a member of current Admin Domain-------------------”
Table 33 lists and describes each item in the Port Detail report.
TABLE 33 Port Detail report columns
Report item Description
LFA Link Loss: the number of link loss occurrences out of range for a specified time period.
LSY Sync Loss: the number of sync loss occurrences out of range for a specified time period.
LSI Signal Loss: the number of signal loss occurrences out of range for a specified time period.
PER Protocol Error: the number of protocol errors out of range for a specified time period.
INW Invalid word. The number of invalid words out of range for a specified time period.
CRC Invalid CRC: the number of CRC errors out of range for a specified time period.
PSC Port hardware state changed too often because of fabric reconfiguration.
BLP Buffer limited port: the switch status changes when a port is in a buffer limited mode based
on the switch status policy.
STM SFP temperature is out of specifications.
SRX SFP receive power is out of specifications.
STX SFP transmit power is out of specifications.
SCU SFP current is out of specifications.
SVO SFP voltage is out of specifications.
Vue de la page 127

Commentaires sur ces manuels

Pas de commentaire