Fabric Watch Administrator’s Guide 85
53-1002153-01
FRU monitoring
8
The following example shows a switch status policy for temperature:
Bad Temperatures contributing to DOWN status: (0..10) [0] 3
Bad Temperatures contributing to MARGINAL status: (0..10) [0] 1
The following example shows a switch status policy for fans:
Bad Fans contributing to DOWN status: (0..3) [0] 2
Bad Fans contributing to MARGINAL status: (0..3) [0] 1
Switch status policies are saved in a nonvolatile memory, and therefore are persistent until
changed.
Viewing your switch status policy
After you have defined and configured your switch status policy, view it with the
switchStatusPolicyShow command. The switchStatusPolicyShow command displays the following
policy parameters that determine the overall switch status.
FCoE and VE ports are not considered in marginal port or faulty port calculations.
Power Supplies—The power supply thresholds detect absent or failed power supplies.
Temperature—Temperature thresholds detect faulty temperature sensors.
FanFan thresholds detect faulty fans.
Flash—Flash thresholds monitor flash memory.
Marginal Ports—Ports that move into the marginal state for reasons such as insufficient buffer
credits.
Port Persistence Time—Fabric Watch waits for the port persistence time duration before it
declares the port to be in MARGINAL state when it crosses the high threshold.
Faulty Ports—Ports that are faulty because of hardware faults, such as invalid SFPs.
Missing SFPs—Monitors the number of ports without SFPs.
Error Ports—Ports that are disabled because of segmentation, an authentication failure, port
fencing, or bottleneck detection.
The policy you defined determines the output in the Switch Status Policy Report.
See Chapter 10, “Fabric Watch Reports,” for more details about the Switch Status Policy Report.
FRU monitoring
Supported FRU areas depend on the type of Brocade switch. For the following switches, the slot
and WWN areas are not supported:
Brocade 300, 5100, and 5300 switches
Brocade DCX and DCX-4S Data Center Backbone
Brocade Encryption Switch